OD-01Survey Meter OD-02

  • Dose meter and dose rate meter for the measurement of the ambient dose and dose rate equivalent H*(10), dH*(10)/dt and the directional dose and dose rate equivalent H'(0.07) , dH'(0.07)/dt of mixed radiation fields (X-rays, gamma and beta radiation) (type approval intended)
  • Radiation detector: air opened ionisation chamber
  • Measuement range: 3 decades for dose and 6 decades for dose rate measurements
  • Automatic switch of the fine measurement ranges
  • Measurement in the soft-radiation region above 6 keV
  • Measurement of hard X-rays and gamma radiation as well as bremsstrahlung of up to 15 MeV (> 15 MeV using an additional acrylic plastic shielding)
  • Measurement of ambient and directional dose and dose rate of pulsed radiation fields
  • Measurement of beta radiation of energies from 80 keV up to 2 Me
  • Detachable probe for remote measurements of up to 100 m
  • Measurements are processed via an internal micro controller and sophisticated algorithms
  • Saving and displaying of maximum dose rate
  • Calculation of dose in Dose-Rate-Mode
  • Easy-to-read back-lit LC-Graphics-Display
  • Battery powered, transportable and stationary applicable device
  • Application for radiation safety measurements in following fields:
    • Medical and technical irradiation units
    • Atomic power plants
    • Laboratories for radioactive nuclides
    • Nuclear medical units
  • Optional equipment:OD-02 Optional Equipment
    • USB cable and software for measurement evaluation via PC
    • Power supply (DC 6 V) with power lead
    • Variable probe extension cable up to 100 m upon customer request
    • Acrylic plastic shielding for energy values E > 15 MeV
    • Wall holder for stationary application

    User Manual OD-02

    Prospect OD-02

Area Dose Rate Meter BD-01** PLEASE DESCRIBE THIS IMAGE **

The Area Dose Rate Meter BD-01 is a hand-held dosimeter for radiation protection measurements during application of beta-nuclides.

Fields of application:

  • Medicine, life-sciences, industry
  • Local dose measurement in mixed beta-gamma radiation fields
  • Evaluation of workstations
  • Retrospective dose assessments
  • Localisation of beta-radiation sources and contamination

Technical Specifications

Download: BD-01 Data Sheet (*.pdf, 111 KB)

Poster-DASA 2003 (*.pdf, 187 kB)


OD-01Survey Meter OD-01

  • Dose meter and dose rate meter for the measurement of the ambient dose and dose rate equivalent H*(10), dH*(10)/dt and the directional dose and dose rate equivalent H'(0.07) , dH'(0.07)/dt of mixed radiation fields (X-rays, gamma and beta radiation) (type approval intended
  • Radiation detector: air opened ionisation chamber
  • Measurement range: 3 decades for dose and 6 decades for dose rate measurements
  • Automatic switch of the fine measurement ranges
  • Measurement in the soft-radiation region above 6 keV
  • Measurement of hard X-rays and gamma radiation as well as bremsstrahlung of up to 15 MeV (> 15 MeV using an additional acrylic plastic shielding)
  • Measurement of ambient and directional dose and dose rate of pulsed radiation fields
  • Measurement of beta radiation of energies from 60 keV up to 3 MeV
  • Detachable probe for remote measurements of up to 100 m
  • Easy-to-read back-lighted LCD panel
  • Battery powered, transportable and stationary applicable device
  • Application for radiation safety measurements in following fields:
    • Medical and technical irradiation units
    • Atomic power plants
    • Laboratories for radioactive nuclides
    • Nuclear medical units
  • Optional equipment:
    • USB cable and software for measurement evaluation via PC
    • Power supply (DC 6 V) with power lead
    • Variable probe extension cable up to 100 m upon customer request
    • Acrylic plastic shielding for energy values E > 15 MeV
    • Wall holder for stationary application
Technical Specifications OD-01

 Download: Prospect OD-01


OD-01HxSurvey Meter OD-01 Hx

  • Follow up model of RGD 27091
  • Dose meter and dose rate meter for the measurement of the photon dose and dose rate equivalent Hx, dHx/dt radiation fields (X-rays, gamma radiation)
  • Radiation detector: air equivalent ionisation chamber
  • Measuement range: 3 decades for dose and 6 decades for dose rate measurements
  • Automatic switch of the fine measurement ranges
  • Measurement in the soft-radiation region above 6 keV
  • Measurement of hard X-rays and gamma radiation as well as bremsstrahlung of up to 15 MeV (>15 MeV using an additional acrylic plastic shielding)
  • Measurement of photon dose and dose rate of pulsed radiation fields
  • Qualitative measurement of beta radiation above energies E > 160 keV
  • Detachable probe for remote measurements of up to 100 m
  • Easy-to-read back-lighted LCD panel
  • Battery powered, transportable and stationary applicable device
  • Application for radiation safety measurements in following fields:
    • Medical and technical irradiation units
    • Atomic power plants
    • Laboratories for radioactive nuclides
    • Nuclear medical units
  • Optional equipment:
    • USB cable and software for measurement evaluation via PC
    • Power supply (DC 6 V) with power lead
    • Variable probe extension cable up to 100 m upon customer request
    • Acrylic plastic shielding for energy values E > 15 MeV
    • Wall holder for stationary application
Technical Specifications OD-01 Hx

Download: Prospect OD-01 Hx




Survey Meter PM1405 (Polimaster)

  • Measurement of the ambient dose rate equivalent of gamma radiation, X-ray and beta radiation flux density
  • Big backlightened LC-display
  • USB Interface for data transmission and as power supply
  • Easy-weighted and compact radiation measuring device
Technical Specifications: Polimaster PM1405



Image

X-Ray-Gamma-Dosimeter RGD 27091 (only maintenance and repair, replaced by OD-01)

  • Because of technical advancements the RGD 27091 has been replaced by the OD-01Hx scince August 2009.

  • We still offer maintenance, service and recalibration of devices.

Electronical multi-use dose meter PM1203M (Polimaster)

  • Measurement of the ambient dose equivalent H*(10) and ambient dose rate equivalent dH*(10)/dt
  • Non-volatile memory
  • Infrared-connection to PC
  • Audible and light alarm at exceeding the defined thresholds
  • Big LC-display with a digital and an analogue scale
  • The battery life-time of a battery set is 1 year
  • Lightweighted and comnpact
  • A clip for carrying in front pocket
Technical Specifications Polimaster PM1203M




Devices to search radiation sources PM1401MA/MB (Polimaster)

  • Fast response time
  • Easy to use
  • Measuring the dose rate of gamma radiation and indicating the dose rate of neutron radiation
  • Alarm when exceeding the dose rate warning thresholds
  • Non-volatile memory used to record all cases
  • IR connection with your PC
  • Hermetically sealed and shock-resistant housing, IP 65
  • Extra accessories: one piece pull-out extension
  • Vibration alert
Technical Specifications: Polimaster PM1401MA/MB



Devices to search radiation sources PM1401GNA/GNB (Polimaster)

  • Fast response time
  • Easy to use
  • Measuring the dose rate of gamma radiation and indicating the dose rate of neutron radiation
  • Alarm when exceeding the dose rate warning thresholds
  • Non-volatile memory used to record all cases
  • IR connection with your PC
  • Hermetically sealed and shock-resistant housing, IP 65
  • Extra accessories: one piece pull-out extension
  • Vibration alert
Technical Specifications: Polimaster PM1401GNA/GNB


print page Top of the page